Approx. Rs 7,000 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 2 Piece |
Media | Air, Water and Gas |
Pressure | Medium Pressure |
Type | Flow Control Valve |
Valve Size | 5,6,10,16 |
Material | Stainless Steel |
Brand | Belimo |
Port Size | 1/8 Inch |
Design | Plain |
Color | Silver |
Fluid Pressure | Cold And Warm Water, Water With Glycol Up To Max. 50% Vol |
Angle Of Rotation | 90 Degree |
Stem Seal | EPDM O-ring |
Saftey Notes
• The valve has been designed for use in stationary heating, ventilation and airconditioning systems and must not be used outside the specified field of application,especially in aircraft or in any other airborne means of transport.• Only authorised specialists may carry out installation. All applicable legal orinstitutional installation regulations must be complied during installation.• The valve does not contain any parts that can be replaced or repaired by the user.• The valve may not be disposed of as household refuse. All locally valid regulationsand requirements must be observed.• When determining the flow rate characteristic of controlled devices, the recogniseddirectives must be observed.
Product Features
Mode of operation
The characterised control valve is adjusted by a rotary actuator. The actuator iscontrolled by a commercially available modulating or 3-point control system and movesthe ball of the valve – the throttling device – to the position dictated by the positioningsignal. Open the characterised control valve counterclockwise and close it clockwise.
Flow characteristic
Equal percentage flow control is ensured by the integrated characterising disc.
Installation Notes
Servicing Ball valves and rotary actuators are maintenance-free.Before any service work on the final controlling device is carried out, it is essential toisolate the rotary actuator from the power supply (by unplugging the electrical cableif necessary). Any pumps in the part of the piping system concerned must also beswitched off and the appropriate slide valves closed (allow all components to cooldown first if necessary and always reduce the system pressure to ambient pressurelevel).The system must not be returned to service until the ball valve and the rotary actuatorhave been correctly reassembled in accordance with the instructions and the pipelinehas been refilled by professionally trained personnel.Flow direction The direction of flow, specified by an arrow on the housing, is to be complied with,since otherwise the ball valve could become damaged. Please ensure that the ball is inthe correct position (marking on the spindle).